PLANCKDefense & AerospaceContact

Autonomy & Edge

Designing edge software for the moment the link goes away

Official planning assumes denied and intermittent communications. Edge software has to settle what runs locally, how it degrades, how it resynchronizes and how it stays secure.

Link loss is a stated planning assumption

The Department of Defense's 2021 strategy for cloud computing outside the continental United States says the most significant challenge for those users is accessing and sharing information in denied, disconnected, intermittent, or limited (D-DIL) environments. The same document notes that users at the tactical edge routinely operate with limited bandwidth and limited size, weight and power.

The link is also a target. Jamming, spoofing and cyber attack can cut it as surely as terrain or distance. Software for unmanned and edge platforms should therefore treat disconnection as a normal operating state with defined, tested behavior.

Decide what must work locally

Start with a list of the functions the mission needs when nothing upstream answers. NIST SP 800-160 Volume 2, Revision 1 calls this objective Continue: maximize the duration and viability of essential functions during adversity. On an edge platform the list usually includes inference, operator control, logging and the access decisions that gate each of them.

Access control is an easy dependency to miss. NIST SP 800-207 warns that if the components that make and enforce access decisions cannot be reached, operations suffer. It suggests replicating policy enforcement in several locations. At the edge, that points to a local decision point with cached policy, and credential lifetimes set against both the longest expected outage and the risk of capture.

Local compute is bounded. A model has to be selected and measured against the processor, memory and power the platform really has. Measurements taken on data center hardware do not carry over.

Degrade in defined steps

Give each connectivity state a name, entry and exit conditions, and a tested behavior. Full link, reduced bandwidth, intermittent and none are a reasonable starting set. NIST uses the term securely resilient for a system that preserves a secure state despite disruption, including during transitions between normal and degraded modes. The transitions deserve as much testing as the states.

The operator should always know which state the system is in and what it will do next. A system that cannot finish a task within the limits its operator set should stop or ask for more input.

Resynchronize on purpose

The 2021 strategy describes the target behavior. Edge devices should preserve operational effectiveness through different degrees of connectivity and synchronize automatically once reconnected. Reintegration should not broadcast the user's location to adversary forces. In practice, that means local queues with priorities, the most valuable data sent first, conflicts resolved by rule, and a limit on how much the device transmits.

Updates travel the same path in the other direction. NIST SP 800-193 calls for authenticated firmware updates, controls against unauthorized rollback to a vulnerable version, and recovery to a state of integrity. It notes that local recovery may be necessary when there is no network connectivity. Joint guidance from NSA, CISA and partner agencies applies similar ideas to AI models: confirm each artifact's origin and integrity, run a full evaluation after any model change, and keep the ability to revert to the last known good state.

Secure the link and the device

Know exactly what the link protocol protects. MAVLink is a messaging protocol used between drones and ground stations. Version 2 offers message signing, which lets a system verify that messages come from a trusted source. The project's documentation states that MAVLink does not provide message encryption, so confidentiality has to come from another layer.

Assume the device can be lost. The joint AI guidance recommends encrypting model weights at rest and keeping the keys in a hardware security module. CISA makes a broader point about unmanned aircraft systems: each point of connection is a potential target, including controllers and docking stations. Ground software belongs in the same threat model as the vehicle.

Planck Defense and Aerospace offers on-device AI and security engineering built on these principles, for platforms that must operate disconnected.

Key points

  • Treat disconnection as a named operating state with tested behavior.
  • Keep inference, access decisions, logging and recovery on the device.
  • Know what the link protocol protects. MAVLink 2 signs messages and does not encrypt them.

Sources

  1. Department of Defense Outside the Continental United States (OCONUS) Cloud Strategy (2021), DoD Chief Information Officer
  2. NIST SP 800-160 Vol. 2 Rev. 1, Developing Cyber-Resilient Systems: A Systems Security Engineering Approach (December 2021), National Institute of Standards and Technology
  3. NIST SP 800-207, Zero Trust Architecture (August 2020), National Institute of Standards and Technology
  4. NIST SP 800-193, Platform Firmware Resiliency Guidelines (May 2018), National Institute of Standards and Technology
  5. Deploying AI Systems Securely: Best Practices for Deploying Secure and Resilient AI Systems (Joint Cybersecurity Information Sheet, April 2024, Ver. 1.0), NSA Artificial Intelligence Security Center, CISA, FBI and partner agencies
  6. MAVLink Developer Guide: Frequently Asked Questions, MAVLink project (Dronecode Project)
  7. UAS Cybersecurity, Cybersecurity and Infrastructure Security Agency

Government publications are cited for information only. Citing them does not imply endorsement by any agency.

Ready to work with us?

From research and rapid prototypes to operational delivery, our team takes on hard problems across cyber, on-premises AI, and secure systems.